Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Int. braz. j. urol ; 44(4): 709-716, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-954076

ABSTRACT

ABSTRACT Purpose: To assess the accuracy of prostate-specific antigen (PSA) adjusted for the transition zone volume (PSATZ) in predicting prostate cancer by comparing the ability of several PSA parameters in predicting prostate cancer in men with intermediate PSA levels of 2.6 - 10.0 ng/mL and its ability to reduce unnecessary biopsies. Materials and Methods: This study included 656 patients referred for prostate biopsy who had a serum PSA of 2.6 - 10.0 ng/mL. Total prostate and transition zone volumes were measured by transrectal ultrasound using the prolate ellipsoid method. The clinical values of PSA, free-to-total (F/T) ratio, PSA density (PSAD) and PSATZ for the detection of prostate cancer were calculated and statistical comparisons between biopsy-positive (cancer) and biopsy-negative (benign) were conducted. Results: Cancer was detected in 172 patients (26.2%). Mean PSA, PSATZ, PSAD and F/T ratio were 7.5 ng/mL, 0.68 ng/mL/cc. 0.25 ng/mL/cc and 0.14 in patients with prostate cancer and 6.29 ng/mL, 0.30 ng/mL/cc, 0.16 ng/mL/cc and 0.22 in patients with benign biopsies, respectively. ROC curves analysis demonstrated that PSATZ had a higher area under curve (0,838) than F/T ratio (0.806) (P<0.001) and PSAD (0.806) (P<0.001). With a cut-off value of 0.22 ng/mL/cc, PSATZ had 100% of sensitivity and could have prevented 24% of unnecessary biopsies. Conclusions: PSATZ may be useful in enhancing the specificity of serum PSA. Compared to other PSA related parameters, it was better in differentiating between prostate cancer and benign prostatic enlargement. Also, PSATZ could reduce a significant number of unnecessary biopsies.


Subject(s)
Humans , Male , Aged , Aged, 80 and over , Prostate/pathology , Prostatic Neoplasms/pathology , Prostatic Neoplasms/blood , Prostate-Specific Antigen/blood , Unnecessary Procedures/statistics & numerical data , Image-Guided Biopsy/statistics & numerical data , Prostatic Hyperplasia/diagnosis , Prostatic Hyperplasia/pathology , Prostatic Hyperplasia/blood , Prostatic Neoplasms/diagnosis , Reference Standards , Reference Values , Prospective Studies , Sensitivity and Specificity , Middle Aged
2.
Rev. Assoc. Med. Bras. (1992) ; 64(2): 148-153, Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-896432

ABSTRACT

Summary Objective: To evaluate the carotid intima-media complex (CIMC) thickness and lipid metabolism biomarkers associated with cardiovascular risk (CR) in parents of patients with ataxia-telangiectasia and verify an association with gender. Method: A cross-sectional and controlled study with 29 ATM heterozygotes and 14 healthy controls. Biochemical tests and CIMC thickness measurement were performed. Results: The mean CIMC measurement in heterozygous ATM was 0.72 ± 0.1 mm (minimum: 0.5 mm and maximum: 1.0 mm). Noticed high percentage of amounts above 75 percentile compared to the population referential (16 [76.2%]), without any significant statistical differences between the female and the male gender (11/15 [73.3%] vs. 5/6 [83.3%]; p=0.550). The comparison between heterozygous and controls, stratified by gender, showed that in heterozygous ATMs, women had higher concentrations of HDL-c compared to men, as well as higher values of hs-CRP in relation to the control women. In heterozygous ATMs, stratified by gender, the correlation between HDL-c and hs-CRP was inversely proportional and stronger among women, with a tendency to statistical significance. Conclusion: Heterozygous ATMs did not differ from controls in relation to the biomarkers studied related to CR. However, most of them presented increased CIMC, independent predictor of death, risk for myocardial infarction and stroke, compared to the referential for the same age group. This finding suggests CR in the heterozygous ATM and shows to the need to monitor CIMC thickness and nutritional orientations.


Resumo Objetivo: Avaliar a espessura do complexo médio-intimal da carótida (CMIC) e os biomarcadores do metabolismo lipídico associados ao risco cardiovascular (RC) em pais de pacientes com ataxia-telangiectasia (AT) e verificar associação com gênero. Método: Estudo transversal prospectivo e controlado com 29 ATM heterozigotos e 14 controles saudáveis. Foram realizados exames bioquímicos e a espessura do CMIC por ultrassonografia. Resultados: A média da medida do CMIC nos ATM heterozigotos foi de 0,72± 0,1 mm (mínimo: 0,5 mm e máximo: 1,0 mm). Observou-se elevado percentual de valores acima do percentil 75 em relação ao referencial populacional (16 [76,2%]), sem diferença estatisticamente significante entre o gênero feminino e o masculino (11/15 [73,3%] vs. 5/6 [83,3%]; p=0.550). A comparação entre os ATM heterozigotos e os controles, estratificados por gênero, mostrou que, nos ATM heterozigotos, as mulheres tinham maiores concentrações de HDL-c em comparação aos homens, e valores mais elevados de PCR-us em relação às mulheres controle. Nos ATM heterozigotos, estratificando segundo gênero, a correlação entre HDL-c e PCR-us foi inversamente proporcional e mais forte entre as mulheres, com tendência à significância estatística. Conclusão: Os ATM heterozigotos não diferiram dos controles em relação aos biomarcadores estudados relacionados ao RC. Entretanto, a maioria deles apresentou aumento na espessura do CMIC, preditor independente de morte, risco para infarto do miocárdio e AVC, quando comparado ao referencial para a mesma faixa etária. Esse achado sugere RC nos ATM heterozigotos e aponta para a necessidade de monitoramento da espessura do CMIC e de orientações nutricionais.


Subject(s)
Humans , Male , Female , Adult , Ataxia Telangiectasia/blood , Cardiovascular Diseases/diagnosis , Carotid Intima-Media Thickness , Heterozygote , Parents , C-Reactive Protein/analysis , Ataxia Telangiectasia/genetics , Biomarkers/blood , Carotid Arteries , Case-Control Studies , Sex Factors , Nutritional Status , Cross-Sectional Studies , Risk Factors , Risk Assessment , Cholesterol, HDL/blood , Middle Aged
4.
São Paulo med. j ; 133(2): 141-150, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-746650

ABSTRACT

CONTEXT AND OBJECTIVE: Positron emission tomography with [18]F-fluoro-2-deoxyglucose (FDG-PET/CT) has been advocated as the method of choice for lymphoma staging, since it enables whole-body analysis with high sensitivity for detection of affected areas and because it combines capacities for anatomical and functional assessment. With technological advances, magnetic resonance imaging (MRI) has emerged as an alternative to FDG-PET/CT. This systematic review with meta-analysis aimed to compare whole-body diffusion-weighted MRI (WB-MRI) with FDG-PET/CT for lymphoma staging. DESIGN AND SETTING: Systematic review on diagnostic test accuracy studies conducted at a public university. METHODS: The Medline, Scopus, Embase and Lilacs databases were searched for studies published up to September 2013 that compared WB-MRI and FDG-PET/CT for lymphoma staging. The reference lists of included studies were checked for any relevant additional citations. RESULTS: Six studies that evaluated the initial lymphoma staging in 116 patients were included. WB-MRI and FDG-PET/CT agreed in 90.5% of the cases (κ = 0.871; P < 0.0001). In most of the studies, when there was disagreement between the methods, WB-MRI overstaged in relation to FDG-PET/CT. The sensitivity of WB-MRI and FDG-PET/CT, in comparison with the clinical-radiological standard, ranged from 59 to 100% and from 63 to 100% respectively. CONCLUSION: WB-MRI is a highly sensitive method for initial lymphoma staging. It has excellent agreement with FDG-PET/CT and is a great alternative for managing lymphoma patients, without using ionizing radiation or an intravenous contrast agent. .


CONTEXTO E OBJETIVO: A tomografia por emissão de pósitrons com 2-[18F]-fluoro-2-deoxi-D-glicose (FDG-PET/CT) tem sido defendida como método de escolha para o estadiamento do linfoma por realizar o estudo do corpo inteiro com boa sensibilidade para detecção das áreas acometidas e por combinar as capacidades de avaliação anatômica e funcional. Com os avanços tecnológicos, a ressonância magnética tem se apresentando como alternativa à FDG-PET/CT. Esta revisão sistemática com metanálise visa comparar a ressonância magnética de corpo inteiro (WB-MRI) com difusão com a FDG-PET/CT no estadiamento do linfoma. TIPO DE ESTUDO E LOCAL: Revisão sistemática de estudos de acurácia diagnóstica conduzida em universidade pública. MÉTODOS: Foi conduzida uma busca nos bancos de dados Medline, Embase, Scopus e Lilacs por estudos publicados até setembro de 2013 comparando a WB-MRI com a FDG-PET/CT no estadiamento do linfoma. As referências bibliográficas dos estudos incluídos foram checadas com a finalidade de encontrar citações adicionais relevantes. RESULTADOS: Foram incluídos seis estudos que avaliaram o estadiamento inicial do linfoma de 116 pacientes. A WB-MRI e a FDG-PET/CT concordaram em 90,5% dos casos (κ = 0,871; P < 0,0001). Na maioria dos estudos, quando houve discordância, a WB-MRI estabeleceu estadiamento superior à FDG-PET/CT. A sensibilidade da WB-MRI e da FDG-PET/CT, em relação ao padrão clínico-radiológico, variou de 59% a 100% e de 63% a 100%, respectivamente. CONCLUSÃO: A WB-MRI apresenta alta sensibilidade no estadiamento inicial do linfoma, excelente concordância com a FDG-PET/CT e representa uma ótima alternativa no manejo de pacientes com linfoma, sem utilizar radiação ionizante ou meio de contraste intravenoso. .


Subject(s)
Humans , Diagnostic Tests, Routine/methods , Diffusion Magnetic Resonance Imaging/methods , Lymphoma/pathology , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods , Confidence Intervals , Hodgkin Disease/pathology , Hodgkin Disease , Lymphoma, Non-Hodgkin/diagnosis , Lymphoma, Non-Hodgkin/pathology , Lymphoma, Non-Hodgkin , Lymphoma , Neoplasm Staging , Sensitivity and Specificity
6.
Radiol. bras ; 46(4): 197-202, Jul-Aug/2013. graf
Article in English | LILACS | ID: lil-684598

ABSTRACT

Objective: To evaluate the necessity of the non contrast-enhanced phase in abdominal computed tomography scans. Materials and Methods: A retrospective, cross-sectional, observational study was developed, evaluating 244 consecutive abdominal computed tomography scans both with and without contrast injection. Initially, the contrast-enhanced images were analyzed (first analysis). Subsequently, the observers had access to the non-contrast-enhanced images for a second analysis. The primary and secondary diagnoses were established as a function of the clinical indications for each study (such as tumor staging, acute abdomen, investigation for abdominal collection and hepatocellular carcinoma, among others). Finally, the changes in the diagnoses resulting from the addition of the non-contrast-enhanced phase were evaluated. Results: Only one (0.4%; p > 0.999; non-statistically significant) out of the 244 reviewed cases had the diagnosis changed after the reading of non-contrast-enhanced images. As the secondary diagnoses are considered, 35 (14%) cases presented changes after the second analysis, as follows: nephrolithiasis (10%), steatosis (3%), adrenal nodule (0.7%) and cholelithiasis (0.3%). Conclusion: For the clinical indications of tumor staging, acute abdomen, investigation of abdominal collections and hepatocellular carcinoma, the non-contrast-enhanced phase can be excluded from abdominal computed tomography studies with no significant impact on the diagnosis. .


Objetivo: Avaliar a necessidade da fase sem contraste nos exames de tomografia computadorizada de abdome. Materiais e Métodos: Foi realizado estudo retrospectivo, transversal e observacional, no qual foram avaliados 244 exames consecutivos de tomografia computadorizada de abdome realizados sem e com a injeção do meio de contraste. Procurou-se estabelecer, mediante análise das fases com o uso do meio de contraste (primeira análise), e posteriormente com o acréscimo da avaliação da fase sem meio de contraste (segunda análise), o diagnóstico principal e os secundários em função da indicação clínica do exame (estadiamento tumoral, abdome agudo, pesquisa de coleção abdominal e hepatocarcinoma, entre outros). Foram medidas as mudanças nos diagnósticos principais e secundários, decorrentes do acréscimo da fase sem meio de contraste. Resultados: Dos 244 casos avaliados, apenas um (0,4%; p > 0,999; não significante) teve o seu diagnóstico modificado após a leitura da fase sem meio de contraste. Com relação aos diagnósticos secundários, 35 exames (14%) foram modificados após a segunda análise, sendo: nefrolitíase (10%), esteatose (3%), nódulo de adrenal (0,7%) e colelitíase (0,3%). Conclusão: Para as indicações clínicas de estadiamento tumoral, abdome agudo, pesquisa de coleção abdominal e carcinoma hepatocelular, a supressão da fase sem meio de contraste não apresentou impacto diagnóstico expressivo. .

7.
Radiol. bras ; 46(3): 134-138, May-Jun/2013. graf
Article in English | LILACS | ID: lil-681931

ABSTRACT

Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. .


Objetivo Comparar a capacidade diagnóstica para esteatose hepática utilizando-se a fase portal com método simplificado de cálculo com a fase sem contraste na tomografia computadorizada de abdome. Materiais e Métodos Foi realizado estudo retrospectivo em 150 pacientes submetidos a tomografia computadorizada de abdome sem e com contraste intravenoso, 100 deles com esteatose hepática e 50 controles. Para diagnóstico de esteatose hepática na fase portal considerou-se um resultado < 104 UH aplicando-se a fórmula [L - 0,3 × (0,75 × P + 0,25 × A)] / 0,7, onde L, P e A representam a atenuação hepática, da veia porta e da aorta, respectivamente. Foram calculados sensibilidade, especificidade, valores preditivos positivos e negativos, utilizando-se a tomografia computadorizada sem contraste intravenoso como padrão de referência. Resultados O método simplificado de cálculo para o diagnóstico de esteatose hepática na fase portal mostrou sensibilidade de 100%, especificidade de 36%, valor preditivo negativo de 100% e valor preditivo positivo de 75,8%. A taxa de falso-positivos foi 64%. Não foram encontrados falso-negativos. Conclusão A utilização da fase portal apresenta elevada sensibilidade para o diagnóstico de esteatose hepática, quando comparada à fase sem contraste da tomografia computadorizada de abdome. Por outro lado, o método apresenta baixa especificidade. .

8.
Radiol. bras ; 46(2): 65-70, mar.-abr. 2013. ilus
Article in Portuguese | LILACS | ID: lil-673347

ABSTRACT

OBJETIVO: Avaliar a necessidade de realização da fase de equilíbrio nos exames de tomografia computadorizada de abdome.MATERIAIS E MÉTODOS: Realizou-se estudo retrospectivo, transversal e observacional, avaliando 219 exames consecutivos de tomografia computadorizada de abdome com contraste intravenoso, realizados num período de três meses, com diversas indicações clínicas. Para cada exame foram emitidos dois pareceres, um avaliando o exame sem a fase de equilíbrio (primeira análise) e o outro avaliando todas as fases em conjunto (segunda análise). Ao final de cada avaliação, foi estabelecido se houve mudança nos diagnósticos principais e secundários, entre a primeira e a segunda análise. Foi utilizada a extensão do teste exato de Fisher para avaliar a modificação dos diagnósticos principais (p < 0,05 como significante).RESULTADOS: Entre os 219 casos avaliados, a supressão da fase de equilíbrio provocou alteração no diagnóstico principal em apenas um exame (0,46%; p > 0,999). Com relação aos diagnósticos secundários, cinco exames (2,3%) foram modificados.CONCLUSÃO: Para indicações clínicas como estadiamento tumoral, abdome agudo e pesquisa de coleção abdominal, a fase de equilíbrio não acrescenta contribuição diagnóstica expressiva, podendo ser suprimida dos protocolos de exame.


OBJECTIVE: To evaluate the role of the equilibrium phase in abdominal computed tomography.MATERIALS AND METHODS: A retrospective, cross-sectional, observational study reviewed 219 consecutive contrast-enhanced abdominal computed tomography images acquired in a three-month period, for different clinical indications. For each study, two reports were issued - one based on the initial analysis of non-contrast-enhanced, arterial and portal phases only (first analysis), and a second reading of these phases added to the equilibrium phase (second analysis). At the end of both readings, differences between primary and secondary diagnoses were pointed out and recorded, in order to measure the impact of suppressing the equilibrium phase on the clinical outcome for each of the patients. The extension of the exact Fisher's test was utilized to evaluate the changes in the primary diagnosis (p < 0.05 as significant).RESULTS: Among the 219 cases reviewed, the absence of the equilibrium phase determined change in the primary diagnosis in only one case (0.46%; p > 0.999). As regards secondary diagnoses, changes after the second analysis were observed in five cases (2.3%).CONCLUSION: For clinical scenarios such as cancer staging, acute abdomen and investigation for abdominal collections, the equilibrium phase is dispensable and does not offer any significant diagnostic contribution.


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Middle Aged , Aged, 80 and over , Abdomen , Abdomen, Acute , Neoplasm Staging , Radiation, Ionizing , Tomography, X-Ray Computed , Contrast Media , Radiation Dosage , Medical Examination , Clinical Protocols/standards
9.
Radiol. bras ; 46(2): 71-74, mar.-abr. 2013. tab
Article in Portuguese | LILACS | ID: lil-673348

ABSTRACT

OBJETIVO: Avaliar a incidência de complicações pós-procedimento nos pacientes submetidos a biópsia prostática transretal guiada por ultrassom no setor de intervenção do Departamento de Diagnóstico por Imagem da Escola Paulista de Medicina - Universidade Federal de São Paulo.MATERIAIS E MÉTODOS: Foram avaliados, via contato telefônico, 132 pacientes submetidos a biópsia de próstata transretal guiada por ultrassom no período de abril/2011 a junho/2011, seguindo o protocolo padrão do nosso setor.RESULTADOS: As complicações pós-biópsia foram categorizadas em maiores e menores de acordo com a necessidade de avaliação médica adicional. Cinquenta e nove pacientes (61,8%) apresentaram complicações, e desses, grande parte (86,4%) apresentou sintomas leves e autolimitados, considerados menores. Oito pacientes (8,2%) apresentaram complicações maiores, sendo que apenas um deles necessitou de tratamento sob regime de internação hospitalar. A retenção urinária foi a complicação maior mais incidente no nosso estudo.CONCLUSÃO: Corroborando outros estudos da literatura, nosso trabalho demonstrou baixa prevalência de complicações maiores após a biópsia prostática transretal.


OBJECTIVE: To evaluate the incidence of postprocedural complications in patients submitted to transrectal ultrasound-guided prostate biopsy at the Unit of Intervention, Department of Imaging Diagnosis of Escola Paulista de Medicina - Universidade Federal de São Paulo.MATERIALS AND METHODS: Telephone interviews were conducted with 132 patients who had undergone transrectal ultrasound-guided prostate biopsy in the period from April 2011 to June 2011, according to the institution's protocol.RESULTS: Post-biopsy complications were categorized into two groups - minor and major complications, according to their need for further clinical evaluation. Complications were reported by 59 patients (61.8%), most of them (86.4%) with mild and self-limited symptoms, classified as minor complications. Eight patients (8.2%) had major complications, one of which required in-hospital treatment. Urinary retention was the major and most common complication.CONCLUSION: The present study has demonstrated a low prevalence of major complications after transrectal prostate biopsy.


Subject(s)
Humans , Male , Adult , Middle Aged , Aged, 80 and over , Biopsy/adverse effects , Biopsy/mortality , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/prevention & control , Clinical Protocols , Dysuria , Fever , Hematuria , Shivering , Ultrasonography , Urinary Retention
12.
Radiol. bras ; 44(4): 205-209, jul.-ago. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-598545

ABSTRACT

OBJETIVO: Estudar o perfil dos pacientes submetidos a biópsia prostática, determinando possíveis padrões que, associados aos níveis de PSA entre 2,6 e 10,0 ng/ml, possam levar a uma diminuição de biópsias desnecessárias. MATERIAIS E MÉTODOS: De 2007 a 2009, foi realizado um estudo transversal com 1.282 indivíduos submetidos a biópsia prostática e que apresentavam níveis de PSA entre 2,6 e 10,0 ng/ml. RESULTADOS: A prevalência de câncer foi de 28,6 por cento. Pacientes com câncer eram, em média, mais idosos, com valores de PSA e densidade de PSA mais altos e menor volume da próstata. Na análise da densidade de PSA, os pacientes com câncer tiveram média de 0,31 ng/ml/cc, enquanto nos pacientes com resultado negativo a média foi de 0,10 ng/ml/cc. Utilizando como critério de positividade para câncer o ponto de corte de densidade de PSA de 0,15 ng/ml/cc, obtivemos especificidade de 74 por cento e sensibilidade de 70 por cento. Para aumentar a sensibilidade é preciso reduzir o ponto de corte. Com o valor 0,09 ng/ml/cc, obtivemos sensibilidade de 84 por cento (IC 95 por cento: 80-87 por cento) e especificidade de 75 por cento (IC 95 por cento: 72-78 por cento). CONCLUSÃO: O uso sistemático da densidade de PSA na indicação de prosseguimento da investigação do paciente com biópsia poderia reduzir a quantidade de procedimentos desnecessários.


OBJECTIVE: To study the profile of patients with PSA level between 2.6 and 10.0 ng/ml and submitted to prostate biopsy, determining possible patterns that might lead to a reduction of unnecessary biopsies. MATERIALS AND METHODS: In the period from 2007 to 2009, a cross-sectional study was developed with 1,282 patients with PSA levels between 2.6 and 10.0 ng/ml, and submitted to prostate biopsy. RESULTS: Cancer prevalence was 28.6 percent. On average, the patients with positive biopsies were older, with higher PSA levels and density, and smaller prostate volume as compared with the patients with negative biopsies. In the analysis of PSA density, the cancer patients averaged 0.31 ng/ml/cc, while patients with negative results averaged 0.10 ng/ml/cc. Utilizing a cutoff value of 0.15 ng/ml/cc for PSA density as a cancer positiveness criterion, the authors obtained sensitivity of 74 percent and specificity of 70 percent. The cutoff value should be reduced to increase the sensitivity. With a cutoff value of 0.09 ng/ml/cc, sensitivity reached 84 percent (CI 95 percent: 80-87 percent), and specificity, 75 percent (CI 95 percent: 72-78 percent). CONCLUSION: The systematic use of PSA density as an indicator to proceed with the investigation of a patient with biopsy could substantially reduce the amount of unnecessary procedures.


Subject(s)
Humans , Male , Adult , Middle Aged , Aged, 80 and over , Adenocarcinoma , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/physiopathology , Prostate-Specific Antigen , Prostate/pathology , Biopsy , Brazil , Cross-Sectional Studies
13.
São Paulo med. j ; 129(4): 250-260, 2011. ilus
Article in English | LILACS | ID: lil-601179

ABSTRACT

CONTEXT AND OBJECTIVE: Mammography is the best method for breast-cancer screening and is capable of reducing mortality rates. Studies that have assessed the clinical impact of mammography have been carried out using film mammography. Digital mammography has been proposed as a substitute for film mammography given the benefits inherent to digital technology. The aim of this study was to compare the performance of digital and film mammography. DESIGN: Systematic review and meta-analysis. METHOD: The Medline, Scopus, Embase and Lilacs databases were searched looking for paired studies, cohorts and randomized controlled trials published up to 2009 that compared the performance of digital and film mammography, with regard to cancer detection, recall rates and tumor characteristics. The reference lists of included studies were checked for any relevant citations. RESULTS: A total of 11 studies involving 190,322 digital and 638,348 film mammography images were included. The cancer detection rates were significantly higher for digital mammography than for film mammography (risk relative, RR = 1.17; 95 percent confidence interval, CI = 1.06-1.29; I² = 19 percent). The advantage of digital mammography seemed greatest among patients between 50 and 60 years of age. There were no significant differences between the two methods regarding patient recall rates or the characteristics of the tumors detected. CONCLUSION: The cancer detection rates using digital mammography are slightly higher than the rates using film mammography. There are no significant differences in recall rates between film and digital mammography. The characteristics of the tumors are similar in patients undergoing the two methods.


CONTEXTO E OBJETIVO: A mamografia é o melhor método para rastreamento do câncer de mama, capaz de reduzir a mortalidade. Os estudos que avaliam seu impacto clínico foram realizados com mamografia em filme. A mamografia digital é proposta para substituir a mamografia em filme com benefícios inerentes à tecnologia digital. O objetivo do estudo foi comparar o desempenho da mamografia digital com a mamografia em filme. TIPO DE ESTUDO: Revisão sistemática e metanálise. MÉTODO: Foram pesquisadas as bases Medline, Scopus, Embase e Lilacs, buscando-se por estudos pareados, coortes e ensaios clínicos randomizados comparando a mamografia digital e a mamografia em filme, quanto à taxa de detecção de câncer, de reconvocação e características dos tumores, publicados até 2009. As referências dos estudos incluídos foram verificadas em busca de citações relevantes. RESULTADOS: Foi incluído um total de 11 estudos, somando 190.322 mamografias digitais e 638.348 em filme. A taxa de detecção do câncer pela mamografia digital foi significantemente maior (risco relativo, RR: 1,17 [95 por cento intervalo de confiança, IC = 1,06-1,29 I² = 19 por cento]) do que pela mamografia em filme. A vantagem da mamografia digital parece maior em pacientes entre 50 e 60 anos. Não houve diferenças significantes nas taxas de reconvocação de pacientes e nas características dos tumores encontrados. CONCLUSÃO: A mamografia digital apresenta taxa de detecção de câncer pouco maior que a mamografia em filme. Não há diferenças significantes nas taxas de reconvocação entre a mamografia digital e a em filme. As características dos tumores são semelhantes em pacientes em ambos os métodos.


Subject(s)
Humans , Female , Middle Aged , Breast Neoplasms , Mammography/methods , X-Ray Film
14.
Radiol. bras ; 43(6): 355-361, nov.-dez. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-571673

ABSTRACT

OBJETIVO: Avaliar a concordância entre o ultrassom Doppler e a ressonância magnética e a reprodutibilidade interobservador desses métodos na quantificação do volume de fluxo portal em indivíduos esquistossomóticos. MATERIAIS E MÉTODOS: Foi realizado estudo transversal, observacional e autopareado, avaliando 21 pacientes portadores de esquistossomose hepatoesplênica submetidos a mensuração do fluxo portal por meio de ressonância magnética (utilizando-se a técnica phase-contrast) e ultrassom Doppler. RESULTADOS: Observou-se baixa concordância entre os métodos (coeficiente de correlação intraclasse: 34,5 por cento [IC 95 por cento]). A reprodutibilidade interobservador na avaliação pela ressonância magnética (coeficiente de correlação intraclasse: 99,2 por cento [IC 95 por cento] / coeficiente de correlação de Pearson: 99,2 por cento / média do fluxo portal = 0,806) e pelo ultrassom Doppler (coeficiente de correlação intraclasse: 80,6 por cento a 93,0 por cento [IC 95 por cento] / coeficiente de correlação de Pearson: 81,6 por cento a 92,7 por cento / média do fluxo portal = 0,954, 0,758 e 0,749) foi excelente. CONCLUSÃO: Há uma baixa concordância entre o ultrassom Doppler e a ressonância magnética na mensuração do volume de fluxo na veia porta. A ressonância magnética e o ultrassom Doppler são métodos reprodutíveis na quantificação do fluxo portal em pacientes portadores de hipertensão porta de origem esquistossomótica, apresentando boa concordância interobservador.


OBJECTIVE: To evaluate the agreement between Doppler ultrasonography and magnetic resonance imaging as well as the interobserver reproducibility of both methods in the measurement of portal blood flow in schistosomal patients. MATERIALS AND METHODS: A cross-sectional, observational, self-paired study evaluated 21 patients with schistosomiasis mansoni submitted to measurement of portal blood flow with phase-contrast magnetic resonance imaging and Doppler ultrasonography. RESULTS: A poor intermethod agreement was observed (intraclass correlation coefficient: 34.5 percent [CI 95 percent]). On the other hand, the interobserver reproducibility was excellent in the evaluation by magnetic resonance imaging (intraclass correlation coefficient: 99.2 percent [CI 95 percent] / Pearson's correlation coefficient: 99.2 percent / portal blood flow = 0.806) and by Doppler ultrasonography (intraclass correlation coefficient: 80.6 to 93.0 percent [CI 95 percent] / Pearson's correlation coefficient: 81.6 percent to 92.7 percent / portal blood flow = 0.954, 0.758 and 0.749). CONCLUSION: There is a poor intermethod agreement in the measurement of portal blood flow. Nevertheless, contrast-phase magnetic resonance imaging and Doppler ultrasonography demonstrated to be reproducible methods presenting excellent interobserver agreement in the quantification of portal blood flow in patients with hepatosplenic schistosomiasis-related portal hypertension.


Subject(s)
Hypertension, Portal , Hypertension, Portal , Portal Vein/physiology , Magnetic Resonance Imaging , Regional Blood Flow , Reproducibility of Results , Schistosomiasis , Ultrasonography, Doppler
15.
Diagn. tratamento ; 15(3)jul. 2010.
Article in Portuguese | LILACS | ID: lil-567233

ABSTRACT

É fato que as radiações ionizantes apresentam potencial lesivo às células, mas nas doses utilizadas para exames de imagem esse potencial é bastante reduzido.Deve-se ter cuidado especial quanto à dose de radiação em gestantes e crianças.Os benefícios dos exames de diagnóstico por imagem adequadamente indicados superam em muito os riscos potenciais.Há exames de diagnóstico por imagem que não fazem uso de radiação ionizante, como a ultrassonografia e a ressonância magnética, que podem constituir alternativas seguras.Os médicos radiologistas, tecnólogos e técnicos em radiologia são treinados a limitar a exposição à radiação ao mínimo necessário para obter os resultados necessários.


Subject(s)
Humans , Diagnostic Imaging/adverse effects , Diagnostic Imaging , Radiation Exposure
16.
São Paulo med. j ; 128(2): 90-95, 2010. ilus, graf
Article in English | LILACS | ID: lil-554262

ABSTRACT

CONTEXT AND OBJECTIVE: The initial method for evaluating the presence of pleural effusion was chest radiography. Isolated studies have shown that sonography has greater accuracy than radiography for this diagnosis; however, no systematic reviews on this matter are available in the literature. Thus, the aim of this study was to evaluate the accuracy of sonography in detecting pleural effusion, by means of a systematic review of the literature. DESIGN AND SETTING: This was a systematic review with meta-analysis on accuracy studies. This study was conducted in the Department of Diagnostic Imaging and in the Brazilian Cochrane Center, Discipline of Emergency Medicine and Evidence-Based Medicine, Department of Medicine, Universidade Federal de São Paulo (Unifesp), São Paulo, Brazil. METHOD: The following databases were searched: Cochrane Library, Medline, Web of Science, Embase and Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs). The references of relevant studies were also screened for additional citations of interest. Studies in which the accuracy of sonography for detecting pleural effusion was tested, with an acceptable reference standard (computed tomography or thoracic drainage), were included. RESULTS: Four studies were included. All of them showed that sonography had high sensitivity, specificity and accuracy for detecting pleural effusions. The mean sensitivity was 93 percent (95 percent confidence interval, CI: 89 percent to 96 percent), and specificity was 96 percent (95 percent CI: 95 percent to 98 percent). CONCLUSIONS: In different populations and clinical settings, sonography showed consistently high sensitivity, specificity and accuracy for detecting fluid in the pleural space.


CONTEXTO E OBJETIVOS: O método inicial para a avaliação da presença dos derrames pleurais foi a radiografia de tórax. Estudos isolados demonstraram que a ultrassonografia apresenta uma acurácia maior que a radiografia para este diagnóstico, entretanto, não se encontram disponíveis na literatura revisões sistemáticas sobre este tema. Assim, o objetivo deste estudo é avaliar a acurácia da ultrassonografia na detecção de derrame pleural, por meio de revisão sistemática da literatura. TIPO DE ESTUDO E LOCAL: Revisão sistemática com metanálise de estudos de acurácia. O estudo foi conduzido no Departamento de Diagnóstico por Imagem e no Centro Cochrane do Brasil/Disciplina de Medicina de Urgência e Medicina Baseada em Evidências do Departamento de Medicina, Universidade Federal de São Paulo (Unifesp), São Paulo, Brazil. MÉTODOS: Foram pesquisadas as seguintes bases de dados: Cochrane Library, Medline, Web of Science, Embase e Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs). As referências de estudos relevantes foram verificadas para adicionais citações de interesse. Foram incluídos estudos nos quais a acurácia da ultrassonografia para a detecção de derrame pleural tenha sido testada, com padrão referência aceitável (tomografia computadorizada ou drenagem torácica). RESULTADOS: Foram incluídos quatro estudos. Todos apresentaram alta sensibilidade, especificidade e acurácia para a detecção de derrame pleural pela ultrassonografia. A sensibilidade média foi de 93 por cento (intervalo de confiança, IC 95 por cento: 89 por cento a 96 por cento), e a especificidade 96 por cento (IC 95 por cento: 95 por cento a 98 por cento). CONCLUSÕES: A ultrassonografia, em diferentes populações e cenários clínicos, apresentou consistentemente alta sensibilidade, especificidade e acurácia na detecção de líquido no espaço pleural.


Subject(s)
Humans , Pleural Effusion , Reproducibility of Results , Sensitivity and Specificity
17.
Radiol. bras ; 42(5): 277-282, set.-out. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-530173

ABSTRACT

OBJETIVO: Descrever as alterações das vias biliares pela colangiografia por ressonância magnética (CPRM) na esquistossomose hepatoesplênica e avaliar a concordância interobservador da CPRM na detecção de colangiopatia esquistossomótica. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 24 pacientes com a forma hepatoesplênica da esquistossomose mansoni e em 6 pacientes sadios, como grupo controle, com avaliação da via biliar pela CPRM. As alterações da via biliar consideradas foram: distorção, afilamento, estenose, dilatação e irregularidade. Foi calculada a concordância interobsevador para alteração da via biliar com o teste de McNemar e o índice kappa (κ). RESULTADOS: A concordância interobservador na caracterização de distorção e afilamento da via biliar foi quase perfeita (κ = 0,867; intervalo de confiança [IC] 95 por cento [0,512-1,0] e κ = 0,865; IC 95 por cento [0,51-1,0], respectivamente). A concordância foi substancial para a estenose (κ = 0,78; IC 95 por cento [0,424-1,0]), moderada para dilatação (κ = 0,595; IC 95 por cento [0,247-0,942]) e regular para afilamento (κ = 0,229; IC 95 por cento [0,095-0,552]). CONCLUSÃO: As alterações observadas nas vias biliares foram, em ordem decrescente de ocorrência: distorção, afilamento, estenose, dilatação e irregularidade. A concordância interobservador para sinais de colangiopatia esquistossomótica foi quase perfeita para distorção e afilamento e substancial para estenose.


OBJECTIVE: To describe changes of the biliary tree demonstrated by magnetic resonance cholangiography (MRC) in patients with the hepatosplenic presentation of schistosomiasis mansoni, and evaluating the interobserver agreement in the detection of schistosomal cholangiopathy. MATERIALS AND METHODS: Prospective, cross-sectional study involving 24 patients with hepatosplenic schistosomiasis and 6 healthy patients (control group) submitted to biliary tree evaluation by MRC. The following changes of the biliary tree were considered: distortion, thinning, stenosis, dilation and irregularity. The interobserver agreement in the detection of biliary tree changes was calculated with the McNemar's test and the kappa index of agreement (κ). RESULTS: The interobserver agreement in the detection of distortion and thinning of the biliary tree was almost perfect (κ = 0.867; confidence interval [CI] 95 percent [0.512-1.0] and κ = 0.865; CI 95 percent [0.51-1.0], respectively). There was a substantial agreement for stenosis (κ = 0.78; CI 95 percent [0.424-1.0]), moderate agreement for dilation (κ = 0.595; CI 95 percent [0.247-0.942]) and mild agreement for thinning (κ = 0.229; CI 95 percent [0.095-0.552]). CONCLUSION: In a decreasing order of frequency, the changes of the biliary tree were observed: distortion, thinning, stenosis, dilation and irregularity. The interobserver agreement for signs of schistosomal cholangiopathy was almost perfect for distortion and thinning, and substantial for stenosis.


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Bile Ducts/abnormalities , Schistosomiasis mansoni/diagnosis , Schistosomiasis mansoni/pathology , Schistosoma/parasitology
18.
Radiol. bras ; 42(5): 289-294, set.-out. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-530175

ABSTRACT

OBJETIVO: Avaliar a eficácia da sequência de ressonância magnética com três excitações, para obtenção de volumes e massas ventriculares, em indivíduos com respiração livre, sem apneia. MATERIAIS E MÉTODOS: Em 32 voluntários sadios, foram comparados os volumes e massas do ventrículo esquerdo, obtidos por meio de duas sequências de ressonância magnética em modo cine. A primeira, tradicionalmente utilizada e considerada padrão, em apneia e com excitação única, e a segunda, em respiração livre e com três excitações. Três leitores, com diferentes níveis de experiência, testaram a concordância e a reprodutibilidade. Para a análise estatística foram utilizados o coeficiente de correlação intraclasse, o teste t-pareado, os gráficos de Bland-Altman e o teste do sinal. RESULTADOS: Para os dois observadores mais experientes, os coeficientes de correlação intraclasse foram superiores a 0,913, assim como os níveis descritivos do teste t-pareado acima de 0,05, os gráficos de Bland-Altman com as diferenças distribuídas aleatoriamente em torno do zero e o teste do sinal com seu nível descritivo superior a 0,05. CONCLUSÃO: A sequência testada apresenta ótima concordância e reprodutibilidade em relação à sequência padrão, podendo ser aplicada em indivíduos com limitações respiratórias.


OBJECTIVE: To evaluate the efficacy of free-breathing magnetic resonance sequence with three excitations in the determination of ventricular volumes and masses in individuals without breathholding. MATERIALS AND METHODS: Left ventricular volumes and masses determined in 32 healthy volunteers through two cine magnetic resonance imaging sequences were compared: the first sequence, traditionally utilized and considered as a standard, performed under apnea, with a single excitation, and the second one, with free-breathing and three excitations. Three observers at different levels of experience evaluated the agreement and reproducibility. Intraclass correlation coefficient, paired t-test, Bland-Altman plots and sign test were utilized for statistical analysis. RESULTS: According to the two most experienced observers, intraclass correlation coefficients were > 0.913, the paired t-test demonstrated P values > 0.05, Bland-Altman plots had differences randomly distributed around zero and the sign test descriptive levels were > 0.05. CONCLUSION: The sequence evaluated presents an excellent agreement and reproducibility as compared with the standard sequence, and can be utilized in patients with respiratory limitations.


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Apnea/diagnosis , Apnea/pathology , Heart Failure, Systolic/diagnosis , Heart Failure, Systolic/pathology , Echocardiography/methods , Magnetic Resonance Spectroscopy/methods
19.
Radiol. bras ; 41(6): 367-372, nov.-dez. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-507116

ABSTRACT

OBJETIVO: Comparar a ressonância de baixo campo (0,2 T) com a de alto campo (1,5 T) na avaliação daendometriose pélvica e adenomiose. MATERIAIS E MÉTODOS: Foram estudadas, prospectivamente, 27 pacientes do sexo feminino com suspeita clínica de endometriose, realizando-se exames de ressonância magnética de alto campo e baixo campo. Um mesmo radiologista realizou a leitura dos exames, iniciando pelo baixo campo, seguido pelo alto campo, usando como padrão-ouro o alto campo. RESULTADOS: Das 27 pacientes estudadas, 18 (66,7%) apresentaram alguma lesão indicativa de endometriose nos exames realizados no alto campo. Foram corretamente diagnosticados pelo baixo campo 14 destas pacientes. Endometriomas, lesões tubárias e focos de endometriose maiores do que 7 mm identificados pelo alto campo foramtambém identificados no baixo campo, com acurácia, sensibilidade e especificidade de 100%. Das novepacientes com adenomiose caracterizadas pelo alto campo, oito foram corretamente identificadas pelo baixo campo, com acurácia, sensibilidade e especificidade de 88,9%. CONCLUSÃO: A ressonância de baixo campo apresentou baixa sensibilidade na detecção de pequenos focos de endometriose, alta sensibilidade na detecção de endometriomas e focos de endometriose grandes, e boa acurácia na detecção da adenomiose quando comparada com a ressonância de alto campo.


Subject(s)
Humans , Female , Adolescent , Adult , Endometriosis/diagnosis , Magnetic Resonance Imaging , Brazil , Observational Studies as Topic , Demography , Prospective Studies
20.
Radiol. bras ; 41(5): 305-308, set.-out. 2008. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-496933

ABSTRACT

OBJETIVO: Avaliar a reprodutibilidade do ultra-som Doppler na quantificação do volume de fluxo portal em pacientes esquistossomóticos. MATERIAIS E MÉTODOS: Estudo prospectivo, transversal, observacional e autopareado, avaliando 21 pacientes portadores de esquistossomose hepatoesplênica, submetidos a mensuração do fluxo portal pelo ultra-som Doppler por três observadores, de forma independente, sendo calculada a concordância entre estes, dois a dois, pelo coeficiente de correlação intraclasse, teste t-pareado e grau de linearidade de Pearson. RESULTADOS: A concordância interobservador foi excelente. O coeficiente de correlação intraclasse variou entre 80,6 por cento e 93,0 por cento (IC a 95 por cento [65,3 por cento ; 95,8 por cento]), com coeficiente de correlação de Pearson variando entre 81,6 por cento e 92,7 por cento e sem diferença estatisticamente significante entre os observadores quanto à média do fluxo portal mensurado pelo ultra-som Doppler (p = 0,954 / 0,758 / 0,749). CONCLUSÃO: O ultra-som Doppler é um método confiável para quantificar o fluxo portal em pacientes portadores de hipertensão porta de origem esquistossomótica, apresentando boa concordância interobservador.


OBJECTIVE: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. MATERIALS AND METHODOS: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. RESULTS: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6 percent to 93.0 percent (IC at 95 percent [65.3 percent ; 95.8 percent]), with the Pearson's correlation coefficient ranging between 81.6 percent and 92.7 percent with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). CONCLUSION: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement.


Subject(s)
Humans , Diagnostic Imaging , Hypertension, Portal/physiopathology , Hypertension, Portal/blood , Hypertension, Portal , Reproducibility of Results , Brazil , Cross-Sectional Studies , Prospective Studies , Regional Blood Flow , Schistosomiasis , Ultrasonography, Doppler
SELECTION OF CITATIONS
SEARCH DETAIL